For qCT

This page contains the DICOM specifications for qCT.

The Modality field in your DICOM file's metadata must be CT. Our API only accepts DICOM files with this value, which should be set by your system before upload.

CriteriaAcceptance Criteria

Slice Thickness

Less than 5 mm

Image Processing Level

Series Level

Patient's Age

More than 18 Years

Number of Slices

More than 100

Modality

CT

Minimum Z-Axis Coverage

200 mm

Maximum Z-Axis Coverage (Configurable)

600 mm

Image Patient Orientation

Axial

File Format

Valid DICOM format

DICOM

Valid Lung NCCTs

Convolution Kernel

Smooth Kernel (Not Bone or Sharp etc.)

Body Part Imaged

Chest or Lung

Scans that contain the following elements will be excluded from processing:

  • Post-operative defects

  • Metal artifacts

  • Excessive motion artifacts

  • Improperly ordered slices

  • Missing slices